What is an air source heat pump and how does it work?

An air source heat pump is an outdoor unit that takes heat from the outside air and transfers it into water for your radiators, underfloor heating and hot water cylinder. A fan draws air over a refrigerant coil, a compressor raises the temperature, and a heat exchanger passes that heat to your central heating water.

The most common type of heat pump in UK homes, explained from the outdoor unit to the radiators, including what a typical retrofit looks like.

What are the main parts of an air source heat pump system?

An air-to-water air source heat pump system usually has three main parts that work together. Understanding each one makes quotes much easier to compare.

  • The outdoor unit. A box with one or two large fans, usually placed against an outside wall or on a base in the garden. It contains the outdoor coil and, in many designs, the compressor and the rest of the refrigerant circuit.
  • The hot water cylinder. Because a heat pump heats water steadily rather than instantly, most installations store hot water in a cylinder. If you currently have a combi boiler, you will need space for one, often in an airing cupboard, loft or utility room.
  • The radiators and pipework. In most UK retrofits the heat pump connects to the existing radiators and pipes, with some radiators upsized where the heat loss calculation shows they are too small for lower flow temperatures.

There will also be controls, pumps, valves, an expansion vessel, a magnetic filter or strainer, and sometimes a buffer tank or low loss header. Our guide on what a heat pump looks like includes a labelled illustration of the indoor and outdoor parts.

How does an air source heat pump work?

The outdoor fan pulls air across a coil filled with cold refrigerant. The refrigerant boils at a very low temperature, so it absorbs heat from the air even in winter and turns into a gas. A compressor then squeezes that gas, raising its temperature. The hot refrigerant passes through a heat exchanger, where it heats the water in your central heating system, before an expansion valve drops its pressure so it can collect more heat.

The heated water is pumped around your radiators or underfloor heating, or diverted to heat the cylinder. The heat pump adjusts its output to the weather, usually through weather compensation, which lowers the flow temperature on milder days to improve efficiency. For a step-by-step diagram, read how does a heat pump work?

What is the difference between a monobloc and a split system?

Air source heat pumps come in two broad layouts. The difference is where the refrigerant circuit ends and the water circuit begins.

Monobloc and split air source heat pumps at a general level
MonoblocSplit
Where the refrigerant circuit sitsSealed entirely inside the outdoor unitShared between outdoor unit and an indoor unit
What runs into the houseWater pipes for the heating circuitRefrigerant pipes to an indoor unit
Installation work on refrigerantNormally none on site, as the circuit is factory sealedRefrigerant connections must be made by an engineer qualified to handle refrigerants
Frost protection of outdoor pipesWater pipes outside need insulation and frost protectionLess water pipework outside
Indoor spaceControls and hydraulic parts indoorsAn indoor unit plus controls

Both layouts are widely used. Neither is automatically better; the right choice depends on the property, the distance between the unit and the cylinder, and the installer's design. If you are offered a split system, ask the installer to confirm that the refrigerant work will be carried out and certified by appropriately qualified engineers. Homeowners should never open, cut or alter refrigerant pipework or connections on any heat pump.

What is a defrost cycle and is it normal?

In cold, damp weather, moisture in the air can freeze on the outdoor coil. Ice blocks airflow and reduces output, so the heat pump periodically runs a defrost cycle. During defrost it may briefly stop heating, the fan may stop, and you may see steam or water around the unit and hear some unusual sounds.

This is normal behaviour. What is not normal is constant icing, a unit encased in ice, or defrost cycles so frequent that the house struggles to stay warm. Those can point to poor placement, blocked drainage, low flow or a setup problem. Our noise and defrost guide explains what to look for and what is safe to check.

What does a typical UK air source retrofit involve?

Most air source heat pumps in the UK replace an existing gas, oil or LPG boiler. A typical project will include:

  • A survey and room-by-room heat loss calculation to decide what size heat pump you need.
  • Checking which radiators need upsizing and whether pipework, including any microbore, is suitable.
  • Choosing a location for the outdoor unit with enough clearance for airflow and access, and considering noise for neighbours and any planning requirements.
  • Finding space for a hot water cylinder if there is not one already.
  • Cleaning the existing system so sludge and debris do not reach the new heat pump.
  • Removing the old boiler, fitting the new equipment, commissioning and handing over the controls.
  • Registering the installation and, where eligible, applying for a grant. See who is eligible for a heat pump grant and how much a heat pump costs.

Why must the existing system be clean and flowing well before fitting?

Years of running on a boiler can leave radiators and pipes holding sludge, magnetite and debris. A boiler running hot in short bursts often hid the effect. A heat pump runs cooler for longer and needs more water flowing through the system, so restrictions that went unnoticed can suddenly matter.

The results can include low flow rate errors, cold radiators and short cycling. Debris can also clog filters and the plate heat exchanger. A thorough clean before the heat pump is connected reduces that risk. It is not a cure for an undersized pipe, an undersized radiator or poor controls, but it removes one avoidable cause. Our before you install guide explains what to ask for.

Frequently asked questions

How does an air source heat pump work in winter?

It keeps absorbing heat from outdoor air because the refrigerant boils at a very low temperature. It works harder when it is colder and runs defrost cycles in damp, cold conditions.

Where does an air source heat pump go?

Usually against an outside wall or on a base in the garden, with clearance for air to flow freely and space for servicing. The installer should consider noise, drainage and any planning rules.

Do I need a hot water cylinder with an air source heat pump?

In most cases, yes. Heat pumps heat water steadily and store it, rather than heating it instantly like a combi boiler.

Is a monobloc or split system better?

Neither is better in every home. Monobloc units keep the refrigerant sealed outside; split units need qualified refrigerant work indoors. Your installer should explain why they recommend one layout.

How long does an air source heat pump installation take?

It depends on the amount of radiator, pipework and cylinder work. Ask your installer for a schedule that includes cleaning the existing system before connection.