Why are some rooms warm and others cold?
When a heat pump keeps some rooms comfortable but not others, the heat pump itself is usually producing heat; the problem is getting it to the right places. Water follows the easiest path, so radiators nearest the heat source or on wider pipes can take more than their share while those at the far end of long or narrow runs receive too little. That is a feature of wet heating systems in general, not of any brand.
What affects circulation to each radiator?
Several things decide how much water reaches each radiator:
- Balancing: lockshield valves set by an engineer so each radiator gets its share.
- Pipe size and length: long or narrow runs, including 8mm and 10mm microbore, carry less.
- Sludge: deposits in pipes and the bottom of radiators restrict flow and reduce output.
- Air: trapped air at the top of radiators reduces the heated area.
- Valves: thermostatic valves turned down, or lockshields closed.
- Radiator size: radiators too small for their room at heat pump temperatures.
See common microbore heating problems and cold radiators and poor heat.
How can I map which rooms are struggling?
After the heating has run for a few hours, go room by room and write down the target and actual temperature, whether the radiator feels warm all over, cold at the bottom or cold at the top, and how far the room is from the heat pump. Note any rooms with thermostatic valves turned down. Repeat on a colder day. A simple map like this often shows a pattern, such as all the cold rooms being on one branch of pipework, that points an engineer straight to the cause.
Why should I avoid turning the temperature up myself?
Raising the flow temperature can make cold rooms a little warmer, but it does so by making the whole system run hotter, which generally reduces heat pump efficiency and raises running costs. It also hides the real cause, whether that is balancing, sludge or an undersized radiator, so the problem returns as soon as the setting goes back.
Settings are part of your installer's commissioned design. Change them only in ways they have shown you, and ask them before making bigger adjustments. We do not describe controller menus here because they vary by equipment. See why is my heat pump flow temperature so high?
What if an LG error code appears?
Record it exactly with a photo, the date and the weather, and look it up only in the documentation for your exact equipment, or ask your installer: [CHECK: error code and meaning from manufacturer manual]. Official information is on the LG UK website.
What should an engineer do about uneven heating?
Reasonable expectations include checking water condition and the filter, confirming valves are open, venting air, measuring or estimating flow, balancing the system, and comparing radiator outputs with each room's heat loss. If sludge is found, the cause should be removed rather than worked around. For repairs under warranty, contact your installer or LG: [CHECK: brand warranty wording + source link]. PowDer Flush is a central heating system cleaning service and does not repair heat pumps; see PowDer Flush.
Never open the indoor or outdoor units or touch refrigerant or electrical parts. Bleeding radiators as your installer has shown you is a reasonable homeowner job.
Do thermostatic radiator valves cause uneven heating?
They can, if they are set very differently from room to room or turned right down in rooms you want warm. Heat pumps generally work best when the system runs steadily, so ask your installer how they intended the valves to be set for your design. Check the valve heads are not stuck or obstructed by curtains and furniture, and note their settings on your room map. Changing one valve at a time and waiting a day before judging the result makes the effect much easier to see than adjusting several at once.
Does this apply to other heat pump brands?
Yes. Nothing here suggests LG units have a particular fault. Uneven warmth, circulation and the risks of unsupported temperature changes are whole-system principles that apply to every make. A clean, balanced system with correctly sized radiators gives any heat pump the best chance. Read sludge and magnetite and before you install.
Frequently asked questions
Why is one room cold with my LG heat pump?
Usually balancing, sludge, air, a closed valve or an undersized radiator. Map which rooms struggle and tell your installer.
Should I turn up the flow temperature to fix cold rooms?
Not without your installer. It usually costs efficiency and hides the real cause.
Can sludge cause uneven heating?
Yes, on any brand. It restricts flow and reduces radiator output, often worst on long or narrow runs.
What does my LG error code mean?
Use the documentation for your exact equipment or ask your installer, which is where the code and its meaning are listed.
Who should I contact about an LG warranty repair?
Your installer or LG. PowDer Flush handles central heating system cleaning only.
Uneven heat traced to sludge?
PowDer Flush provides central heating system cleaning, not LG repairs or manufacturer support. If your installer has found sludge or restricted pipework behind uneven heating, call to talk about cleaning. See microbore problems.
Related pages
Before You Install
Why an old system should be properly cleaned before a heat pump is connected.
Read moreFaults by brand
Independent, general fault guidance for Vaillant aroTHERM, Mitsubishi Ecodan, Daikin Altherma, Samsung and LG owners.
Read moreCold radiators and poor heat
Cold spots, rooms that never reach temperature, and heat output lower than expected.
Read moreCommon microbore heating problems
Blockages, sludge, cold radiators, noisy pipes and poor circulation: why small-bore pipes block and how to spot it.
Read more