Why does a high flow temperature matter for a heat pump?
A heat pump moves heat from outside air into your heating water. The hotter it has to make that water, the harder it works for each unit of heat delivered. In general, lower flow temperatures mean better efficiency and lower running costs. Exact efficiency figures depend on the model and conditions: [CHECK: efficiency vs flow temperature data from manufacturer, with source].
A heat pump running consistently hotter than its design flow temperature is a sign that something in the system is not delivering heat as planned. See heat pump running costs for the wider picture.
Is weather compensation set too high?
Most heat pumps use weather compensation: the flow temperature rises as the outdoor temperature falls, following a curve set by the installer. If the curve is set too steep or too high, the heat pump will run hotter than needed in all weather. Curves are often set conservatively at commissioning to avoid complaints, and never revisited.
Adjusting the curve is usually something your installer should do or show you how to do. Changing it without understanding the settings can leave rooms cold or make things worse. Ask your installer what the design flow temperature was and whether the curve matches it.
Are the radiators too small for a heat pump?
Radiators deliver less heat at lower water temperatures. If a radiator was sized for a boiler and is too small for its room at heat pump temperatures, the only way to heat that room is to raise the flow temperature for the whole house. One undersized radiator in a high-heat-loss room can push the entire system hotter.
The fix is usually to upsize or add radiators in the rooms that need them, or to reduce those rooms' heat loss. See do you need bigger radiators for a heat pump?
Can a dirty system force a heat pump to run hotter?
Yes. Sludge in the bottom of radiators reduces the surface that gives off heat, so a radiator that should be big enough behaves like a smaller one. Sludge and magnetite in pipes reduce flow, so less heat reaches the far radiators. In both cases rooms fall short, and the usual response, from the homeowner or an engineer on a callback, is to turn the flow temperature up.
That treats the symptom and costs money every day the heating runs. Cleaning the system can restore radiator output and flow, sometimes allowing a lower flow temperature. We recommend PowDer Flush for this; see sludge and magnetite and, if you have narrow pipework, cleaning microbore pipes. Cleaning cannot fix undersized radiators or a poor design.
What else can make the flow temperature high?
Other causes include:
- Hot water production, which normally needs a higher temperature than space heating for a period.
- Anti-legionella or cylinder sterilisation cycles, set by the installer: [CHECK: cycle settings from manufacturer manual].
- Thermostatic radiator valves turned down, starving rooms and causing the system to work harder.
- Poor balancing, so some rooms get too much flow and others too little.
- A heat pump that is undersized for the home's heat loss.
- A one-pipe system or other layout that delivers cooler water to some radiators. See one-pipe systems.
What can homeowners safely check?
Check whether the high temperature appears all the time or only during hot water cycles. Note the outdoor temperature when you see it. Check TRVs in cold rooms are open. Feel radiators for cold bottoms, which suggest sludge. Look at your controller's settings only in the ways your installer has shown you. Do not open the heat pump or change settings you do not understand.
How can you tell what flow temperature your heat pump is running at?
Many controllers and apps show the current flow temperature, and sometimes the return temperature too. Your installer can show you where to find them. Look at the readings at different outdoor temperatures and during hot water cycles, and note them down with the date and weather. That record makes it much easier for your installer to see whether the weather compensation curve, the radiators or the flow through the system is the problem, rather than guessing from a single visit on a mild day.
When should you call your installer?
Call your installer if the heat pump is running well above its design flow temperature in ordinary weather, if some rooms never reach temperature, or if running costs are well above the estimate. Ask them to review the weather compensation curve, check flow rates and balancing, compare radiator outputs against the heat loss design, and check water condition. If you are planning a heat pump, read before you install so the system starts clean.
Frequently asked questions
Why is my heat pump flow temperature too high?
Usually weather compensation set too high, radiators too small, or poor flow from sludge or restrictions. Ask your installer to check.
What flow temperature should my heat pump run at?
Whatever your installer designed for your home, which varies with outdoor temperature. Ask for the design figure: [CHECK: design flow temperature from installer design].
Does a high flow temperature increase running costs?
Generally yes, because the heat pump works less efficiently at higher temperatures.
Can sludge make my heat pump run hotter?
Yes. It reduces radiator output and flow, so the system needs hotter water to heat the rooms.
Should I turn the flow temperature down myself?
Only within settings your installer has shown you. Lowering it without fixing the cause can leave rooms cold.
Talk to PowDer Flush before you fit a heat pump
Planning a heat pump on an older system, or chasing a fault on a recent install? Call PowDer Flush for straightforward advice about cleaning the system first. Read our before you install guide for the full picture.
Related pages
Before You Install
Why an old system should be properly cleaned before a heat pump is connected.
Read moreRadiators for heat pumps
Lower flow temperatures, heat output, when existing radiators can stay and why cleaning them matters.
Read moreSludge and magnetite
What magnetite is, where it comes from, black water, cold radiators, low flow errors and how it is removed.
Read moreCold radiators and poor heat
Cold spots, rooms that never reach temperature, and heat output lower than expected.
Read more