Microbore

Should you replace microbore pipework?

You should replace microbore pipework when a proper heat loss and flow design shows a run cannot carry the water the heat pump needs, even when clean, or when the pipe is damaged. Where runs are marginal or simply dirty, a thorough clean may be a sensible alternative. Re-piping usually means lifting floors and redecorating, so it is worth getting the decision right.

Re-piping is sometimes exactly the right call. It is also disruptive, and it should be based on a design, not a guess. Here is what it involves, what affects the cost, and how it compares with cleaning.

What does replacing microbore pipework involve?

Replacing microbore usually means running new, larger pipes, often 15mm, to some or all radiators, and sometimes upsizing the main runs too. Because microbore was typically laid under floors and along walls, getting new pipe in usually means:

  • Lifting carpets, flooring and floorboards, sometimes in several rooms.
  • Notching or drilling joists within safe limits, which is a job for a competent installer.
  • Draining the system and removing or disconnecting radiators.
  • Running pipes on the surface or boxing them in where floors cannot be lifted.
  • Refilling, venting and testing the system.
  • Making good: refitting floors, filling, redecorating and sometimes replacing damaged flooring.

How much does replacing microbore pipework cost?

We do not publish cost figures for re-piping, because they vary so widely between homes and change over time. Any typical figure should come from current local quotes: [CHECK: typical cost range for replacing microbore, with source and date].

What we can say is what drives the cost up or down:

  • How many radiators need new pipe, and how long the runs are.
  • Floor construction: suspended timber is easier than solid concrete or screed.
  • Floor finishes: fitted carpet is simpler than tiles, engineered wood or kitchen units.
  • Whether the work happens alongside other jobs, such as radiator upgrades or rewiring.
  • Making good and redecoration, which homeowners often underestimate.
  • Access issues such as upper-floor rooms, boxed-in risers or built-in furniture.

Microbore vs 15mm: what is the difference for a heat pump?

15mm pipe has a noticeably larger internal bore than 8mm or 10mm microbore, so it can carry more water for the same resistance. That gives a heat pump designer more margin, particularly for rooms with higher heat loss. It is also more tolerant of minor deposits, because a thin layer takes up less of the space inside.

Exact flow capacities depend on pipe material, run length, fittings and the acceptable pressure drop in the design, so we do not quote them: [CHECK: flow capacity of 8mm, 10mm and 15mm pipe from the installer's design tables, with source]. Our microbore flow rate guide explains why these figures matter.

Should you clean or replace microbore?

This comparison reflects our professional view, from around twenty years of system flushing. It is a general guide, not a substitute for your installer's design.

Cleaning versus replacing microbore: our professional view
FactorCleaning retained microboreReplacing microbore
Suitable whenThe design shows the run can carry the required flow when cleanThe run is undersized for the design even when clean, or is damaged
DisruptionUsually limited to radiators and access pointsFloors up, furniture moved, redecoration
Cost[CHECK: typical cost range][CHECK: typical cost range]
Fixes sludgeYes, removes deposits from pipes and radiatorsNew pipe is clean, but retained radiators still need cleaning
Fixes undersizingNoYes
Main riskMarginal runs may still struggle in very cold weatherDisruption, making good and cost

When is replacing microbore genuinely needed?

Replacement is the right answer in several situations, and we would recommend it ourselves:

  • The heat loss design shows a run cannot carry the required flow even when perfectly clean.
  • Pipes are kinked, crushed, corroded or leaking.
  • Previous cleaning has not restored adequate flow.
  • Several high-heat-loss rooms share a long microbore circuit.
  • You are already lifting floors for other work, so the extra disruption is small.

No clean can guarantee to overcome a design problem. If the numbers say re-pipe, re-pipe.

What are the alternatives to full re-piping?

Partial re-piping is common: replace the runs that fail the design and keep the ones that pass. Reducing heat loss through insulation or draught-proofing can bring a marginal room within what its microbore can carry. Larger or additional radiators can let the system work at lower flow temperatures, though they also need adequate flow. And cleaning retained runs gives them their full original capacity.

We recommend PowDer Flush for cleaning retained microbore, explained in cleaning microbore pipes. Whatever you choose, read before you install.

How should you compare re-piping quotes?

Ask each installer to list which runs they will replace, the new pipe sizes, how the work will be routed, what making good is included and whether redecoration is your responsibility. Ask whether retained radiators and pipework will be cleaned. Comparing like with like avoids surprises when the floorboards come up.

Do you still need a clean if you re-pipe?

In most cases, yes. Re-piping usually keeps the existing radiators, and steel radiators that have been in service for decades often hold sludge. If they are reconnected without cleaning, that sludge moves into new pipe and onward to the heat pump's strainer and heat exchanger. See cleaning radiators before a heat pump.

Frequently asked questions

How much does it cost to replace microbore with 15mm?

It varies with the number of radiators, floor types and making good. We do not publish figures: [CHECK: typical cost range from current quotes]. Get itemised quotes.

Is 15mm better than microbore for a heat pump?

15mm carries more water for the same resistance, which gives more design margin. Whether microbore is adequate depends on your rooms' heat loss and the design.

Can I keep some microbore and replace the rest?

Yes, partial re-piping is common. The design should identify which runs pass and which fail.

Does re-piping mean lifting every floor?

Not always. Some runs can be surface-mounted or routed differently. Your installer will explain the options for your home.

Can cleaning avoid replacing microbore?

Where a run is adequate when clean, yes. Where it is undersized for the design, no clean can fix that.