Microbore hub

Microbore pipes and heat pumps

Microbore is narrow 8mm or 10mm heating pipework, common in UK homes fitted in the 1970s and 1980s. It can sometimes stay when a heat pump is fitted, but suitability depends on the heat loss calculation, flow design and pipe condition. Deposits can restrict circulation, but cleaning cannot correct unsuitable pipe sizing or an inadequate design.

We have spent around twenty years flushing heating systems, and microbore is our specialism. This hub explains what microbore is, why heat pumps are less forgiving of it than boilers, and links to every microbore guide on the site.

What is microbore pipework?

Microbore is the name for the narrow copper pipes, usually 8mm or 10mm in outside diameter, that feed radiators in many UK homes. Standard radiator pipework is more often 15mm, with larger 22mm or 28mm pipes used for the main runs near the heat source. Microbore became popular in the 1970s and 1980s because it was quick to install, easy to bend by hand, cheap in copper and easy to hide under floors and along skirting boards.

A typical microbore layout has one or more manifolds, often hidden under a floorboard or inside a cupboard, with pairs of thin pipes running from the manifold to each radiator. Some homes have microbore throughout. Others have a mixture, with microbore added to an extension or a loft conversion while the original rooms run on 15mm. Many homeowners do not know they have it until an engineer lifts a board.

How can you tell if you have microbore?

Look at the pipes where they come out of the floor or wall at a radiator valve. Microbore is noticeably thinner than a pencil-width 15mm pipe and is often bent in smooth curves rather than joined with elbows. You may also find a reducer at the valve where the thin pipe meets a standard fitting.

Do not lift floorboards near pipes or cables to find out. Your heating engineer or heat pump surveyor can confirm pipe sizes during the survey, and they should record them, because the sizes feed directly into the flow design.

Why does microbore matter more for a heat pump than a boiler?

A boiler usually heats water to a high temperature and pushes a modest volume of it around the system. A heat pump works efficiently at much lower flow temperatures, so to deliver the same heat into a room it generally needs to move more water. More water through the same narrow pipe means more resistance, and the heat pump's circulating pump has to work against it.

That is the design side. The condition side matters just as much. Microbore has a small internal bore, so a layer of sludge or magnetite that would barely be noticed in a 22mm pipe can take up a large share of the space inside an 8mm one. A system that looked fine on a boiler can show low flow errors and cold radiators within weeks of a heat pump being connected. Exact flow and pressure figures depend on the design, so any figure should come from your installer's calculation: [CHECK: design flow rate and pipe sizing method used by the installer, with source].

Does microbore always have to be ripped out for a heat pump?

No, not always. It is common to hear that microbore and heat pumps never mix. In our experience the honest answer is that it depends on three things: how much heat each room needs, how much water each microbore run has to carry to deliver that heat, and what condition the pipes are in. Some short microbore runs to small rooms with low heat loss can work. Long runs to large, poorly insulated rooms often cannot.

Equally, cleaning is not a cure-all. If a run is simply too small for the flow the design requires, no amount of cleaning will make it bigger, and re-piping that section is the right answer. Our guide can you use microbore with a heat pump? goes through this decision step by step.

What should you do if you have microbore and want a heat pump?

Start with a proper survey and room-by-room heat loss calculation from your installer. Ask them to identify every microbore run, to state the flow each one needs to carry, and to explain whether they intend to keep it, clean it or replace it.

Where microbore is being kept, have it cleaned properly before the heat pump is connected. A thorough clean gives the installer a true picture of the system, and gives the heat pump the best chance of hitting its design flow from day one. Where some runs are being replaced, cleaning the remaining system still matters, because sludge from the old radiators will otherwise travel into new pipework and the new heat pump.

  • Get a heat loss calculation and flow design from your installer.
  • Ask which microbore runs are being kept and why.
  • Have retained pipework and radiators cleaned before connection.
  • Fit appropriate filtration and inhibitor afterwards, as advised by the installer.
  • Keep written records of the survey, the clean and commissioning.

Why is microbore our specialism?

The team behind this site has spent around twenty years flushing heating systems, and microbore systems are where we have built most of our expertise. They are fiddly, they block easily and many standard flushing approaches struggle to move water through them hard enough to shift settled deposits. We recommend PowDer Flush as our method for cleaning microbore before a heat pump retrofit. That is a recommendation based on our own field experience, not a laboratory comparison.

We would rather tell you honestly that a run needs replacing than sell you a clean that will not solve the problem. If the design says the pipe is too small, it is too small.

When real microbore jobs are written up with before and after measurements, they will appear in our microbore and system cleaning case studies.

Where can you find official guidance?

For government schemes and consumer guidance on heat pumps, see GOV.UK. Installation standards for certified heat pump installers are published in the MCS standards and tools library. British Standards, including BS 7593 on the preparation and maintenance of heating system water, are available from BSI Knowledge. Read before you install for the wider picture of preparing a system.

Frequently asked questions

Is microbore pipe 8mm or 10mm?

Both sizes are common in UK homes and are usually called microbore. Some homes also have 6mm sections. Your surveyor should confirm the actual sizes on site.

Can a heat pump run on microbore pipes?

Sometimes. It depends on each room's heat loss, the flow each run must carry and the condition of the pipes. A proper design will tell you which runs can stay. See our full answer.

Why do microbore pipes block so easily?

The bore is small, so sludge and magnetite take up a larger share of the space inside. Low points, tight bends and manifolds collect debris. Read about common microbore heating problems.

Is cleaning microbore cheaper than replacing it?

Usually a clean is less disruptive than lifting floors, but costs vary by home and we do not publish prices here: [CHECK: typical cost range from current quotes]. See replacing microbore pipework.

Who should decide whether my microbore stays?

Your heat pump installer, based on a heat loss calculation and flow design. A cleaning specialist can tell you about the pipes' condition, but sizing decisions belong with the designer.

Got microbore and planning a heat pump?

Call PowDer Flush about central heating system cleaning on microbore systems. We will talk through your pipework, your installer's design and whether a clean before installation makes sense. Read cleaning microbore pipes first if you want the detail.

Central heating system cleaning by PowDer Flush Call 07418 608497